Núñez SS, Ortuño N, Fernández-Durán S, Moltó J, Conesa JA. Analysis and removal of bisphenols in recycled plastics using polyethylene glycol. Sci Rep. 2024;14(1):12824.
Article PubMed PubMed Central Google Scholar
Goodman JE, Peterson MK. Bisphenol A. In: Wexler P, editor. Encyclopedia of toxicology (third edition). Oxford: Academic Press; 2014. p. 514–8.
Sharma V, Jain D, Rai AR, Kumari P, Nagar V, Kaur A, Singh A, Verma RK, Pandey H, Sankhla MS. Toxicological assessment and concentration analysis of Bisphenol A in food grade plastics: a systematic review. Mater Today: Proc. 2023;95:18–25.
Palsania P, Singhal K, Dar MA, Kaushik G. Food grade plastics and bisphenol A: associated risks, toxicity, and bioremediation approaches. J Hazard Mater. 2024;466: 133474.
Article CAS PubMed Google Scholar
Vom Saal FS, Vandenberg LN. Update on the health effects of bisphenol A: overwhelming evidence of harm. Endocrinology. 2021. https://doi.org/10.1210/endocr/bqaa171.
Karrat A, Amine A. Solid-phase extraction combined with a spectrophotometric method for determination of Bisphenol-A in water samples using magnetic molecularly imprinted polymer. Microchem J. 2021;168: 106496.
Zhuang Y, Zhou M, Gu J, Li X. Spectrophotometric and high performance liquid chromatographic methods for sensitive determination of bisphenol A. Spectrochim Acta Part A Mol Biomol Spectr. 2014;122:153–7.
Arce MM, Ortiz MC, Sanllorente S. HPLC-DAD and PARAFAC for the determination of bisphenol-A and another four bisphenols migrating from BPA-free polycarbonate glasses. Microchem J. 2021;168: 106413.
Pop C-E, Miu BA, Németh D, Wolff R, Mihăilescu DF, Avramescu SM, Mernea M. Bisphenol A analysis and quantification inconsistencies via HPLC-UV: a systematic review with technical notes. Discov Appl Sci. 2024;6(4):171.
Yin H, Sun T, Zhou T, Liu X, Pan Y, Wang Y, Liu D. Simultaneous determination of nine APs and BPA in water by solid-phase extraction and GC–MS analysis. Chin J Anal Chem. 2023;51(7): 100258.
Voutsa D. Analytical methods for determination of bisphenol A. In: Eliades T, Eliades G, editors. Plastics in dentistry and estrogenicity: a guide to safe practice. Berlin Heidelberg: Springer; 2014. p. 51–77.
Errico S, Chioccarelli T, Moggio M, Diano N, Cobellis G. A new LC-MS/MS method for simultaneous and quantitative detection of bisphenol-A and steroids in target tissues: a power tool to characterize the interference of bisphenol-A exposure on steroid levels. Molecules. 2019. https://doi.org/10.3390/molecules25010048.
Article PubMed PubMed Central Google Scholar
Ragavan KV, Rastogi NK, Thakur MS. Sensors and biosensors for analysis of bisphenol-A. TrAC Trends Anal Chem. 2013;52:248–60.
Huang L, Wang X, Liu S, Gao ZX. Application of aptamer-based biosensor in bisphenol a detection. Chin J Anal Chem. 2021;49(2):172–83.
Hidayat R, Wahyuningsih S, Fadillah G. Green synthesis approach to produce TiO2/rGO nanocomposite as voltammetric sensor for monitoring trace level bisphenol-A. Mater Sci Engin B. 2022;286: 116083.
Fadillah G, Triana S, Chasanah U, Saleh TA. Titania-nanorods modified carbon paste electrode for the sensitive voltammetric determination of BPA in exposed bottled water. Sens Biosens Res. 2020;30: 100391.
Piriya VSA, Joseph P, Daniel SCGK, Lakshmanan S, Kinoshita T, Muthusamy S. Colorimetric sensors for rapid detection of various analytes. Mater Sci Engin C. 2017;78:1231–45.
Yang FQ, Ge L. Colorimetric sensors: methods and applications. Sensors (Basel). 2023;23(24):9887.
Karrat A, Amine A. Paper-based analytical device for one-step detection of Bisphenol-A using functionalized chitosan. Chemosensors. 2022;10(11):450.
Fadillah G, Toda K, Ohira SI. One-stage chiral enrichment process by continuous flow electrodialysis with molecularly imprinted membrane. Sep Purif Technol. 2023;305: 122492.
Fadillah G, Hidayat R, Yanti I, Fatimah I, Saleh TA. Electrochemical-assisted synthesis of molecularly imprinted graphene oxide/magnetite for highly selective enantiomer separation. Microchem J. 2024;200: 110354.
Kong Q, Wang Y, Zhang L, Ge S, Yu J. A novel microfluidic paper-based colorimetric sensor based on molecularly imprinted polymer membranes for highly selective and sensitive detection of bisphenol A. Sens Actuators B Chem. 2017;243:130–6.
El Hani O, Karrat A, Digua K, Amine A. Advanced molecularly imprinted polymer-based paper analytical device for selective and sensitive detection of Bisphenol-A in water samples. Microchem J. 2023;184: 108157.
Guo W, Hu W, Pan J, Zhou H, Guan W, Wang X, Dai J, Xu L. Selective adsorption and separation of BPA from aqueous solution using novel molecularly imprinted polymers based on kaolinite/Fe3O4 composites. Chem Engin J. 2011;171(2):603–11.
Wang J, Liang R, Qin W. Improvement of the selectivity of a molecularly imprinted polymer-based potentiometric sensor by using a specific functional monomer. Anal Chim Acta. 2024;1298: 342412.
Article CAS PubMed Google Scholar
Lamaoui A, María Palacios-Santander J, Amine A, Cubillana-Aguilera L. Computational approach and ultrasound probe–assisted synthesis of magnetic molecularly imprinted polymer for the electrochemical detection of bisphenol A. Mater Sci Engin B. 2022;277: 115568.
Adithya Krishnan M, Saranyaparvathi S, Raksha C, Vrinda B, Girish CG, Kulkarni NV, Kharisov BI. Transition metal complexes of 4-Aminoantipyrine derivatives and their antimicrobial applications. Russ J Coord Chem. 2022;48(11):696–724.
Paulraj MS. Phenol sensing studies by 4-Aminoantipyrine method-A review. Org Med Chem Int J. 2018. https://doi.org/10.19080/OMCIJ.2018.05.555657.
Soda Y, Bakker E. Quantification of colorimetric data for paper-based analytical devices. ACS Sens. 2019;4(12):3093–101.
Comments (0)