Initial demonstration of the Scratch-PET concept: an intraoperative PET with a hand-held detector

Sanai N, Berger MS. Surgical oncology for gliomas: the state of the art. Nat Rev Clin Oncol. 2018;15:112–25.

Article  PubMed  Google Scholar 

Haque R, Contreras R, McNicoll MP, Eckberg EC, Petitti DB. Surgical margins and survival after head and neck cancer surgery. BMC Ear Nose Throat Disord. 2006;6:2.

Article  PubMed  PubMed Central  Google Scholar 

Houssami N, Macaskill P, Luke Marinovich M, Morrow M. The association of surgical margins and local recurrence in women with early-stage invasive breast cancer treated with breast-conserving therapy: a meta-analysis. Ann Surg Oncol. 2014;21:717–30.

Article  PubMed  PubMed Central  Google Scholar 

Sugarbaker PH. Colorectal cancer: prevention and management of metastatic disease. Biomed Res Int. 2014;2014: e782890.

Article  Google Scholar 

Meershoek P, van Oosterom MN, Simon H, Mengus L, Maurer T, van Leeuwen PJ, et al. Robot-assisted laparoscopic surgery using DROP-IN radioguidance: first-in-human translation. Eur J Nucl Med Mol Imaging. 2019;46:49–53.

Article  CAS  PubMed  Google Scholar 

Heidkamp J, Scholte M, Rosman C, Manohar S, Fütterer JJ, Rovers MM. Novel imaging techniques for intraoperative margin assessment in surgical oncology: a systematic review. Int J Cancer. 2021;149:635–45.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Vahrmeijer AL, Hutteman M, Van Der Vorst JR, Van De Velde CJH, Frangioni JV. Image-guided cancer surgery using near-infrared fluorescence. Nat Rev Clin Oncol. 2013;10:507–18.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Tummers WS, Miller SE, Teraphongphom NT, Gomez A, Steinberg I, Huland DM, et al. Intraoperative pancreatic cancer detection using tumor-specific multimodality molecular imaging. Ann Surg Oncol. 2018;25:1880–8.

Article  PubMed  PubMed Central  Google Scholar 

Stummer W, Pichlmeier U, Meinel T, Wiestler OD, Zanella F, Reulen H-J. Fluorescence-guided surgery with 5-aminolevulinic acid for resection of malignant glioma: a randomised controlled multicentre phase III trial. Lancet Oncol. 2006;7:392–401.

Article  CAS  PubMed  Google Scholar 

Van Oosterom MN, Rietbergen DDD, Welling MM, Van Der Poel HG, Maurer T, Van Leeuwen FWB. Recent advances in nuclear and hybrid detection modalities for image-guided surgery. Expert Rev Med Devices. 2019;16:711–34.

Article  PubMed  Google Scholar 

Vidal-Sicart S, Valdés Olmos RA. New devices in radioguided surgery. Clin Transl Imaging. 2023;11:545–57.

Article  Google Scholar 

Pitre S, Ménard L, Ricard M, Solal M, Garbay J-R, Charon Y. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience. Eur J Nucl Med. 2003;30:339–43.

Article  Google Scholar 

Fusco JC, Seynnaeve BKN, Davit AJ, Czachowski MR, Joyce JM, Gaines BA, et al. Use of intraoperative nuclear imaging leads to decreased anesthesia time and real-time confirmation of lesion removal. J Pediatr Surg. 2018;53:77–80.

Article  Google Scholar 

Yamamoto S, Matsumoto K, Senda M. A large field of view coincidence imaging system based on one-dimensional sharing block detectors. IEEE Trans Nucl Sci. 2009;56:2672–7.

Article  Google Scholar 

Heller S, Zanzonico P. Nuclear probes and intraoperative gamma cameras. Semin Nucl Med. 2011;41:166–81.

Article  PubMed  Google Scholar 

Matthies P, Gardiazabal J, Okur A, Vogel J, Lasser T, Navab N. Mini gamma cameras for intra-operative nuclear tomographic reconstruction. Med Image Anal. 2014;18:1329–36.

Article  PubMed  Google Scholar 

Mathelin C, Salvador S, Huss D, Guyonnet J-L. Precise localization of sentinel lymph nodes and estimation of their depth using a prototype intraoperative mini γ-camera in patients with breast cancer. J Nucl Med. 2007;48:623–9.

Article  PubMed  Google Scholar 

Bluemel C, Schnelzer A, Okur A, Ehlerding A, Paepke S, Scheidhauer K, et al. Freehand SPECT for image-guided sentinel lymph node biopsy in breast cancer. Eur J Nucl Med Mol Imaging. 2013;40:1656–61.

Article  PubMed  Google Scholar 

Kogler AK, Polemi AM, Nair S, Majewski S, Dengel LT, Slingluff CL, et al. Evaluation of camera-based freehand SPECT in preoperative sentinel lymph node mapping for melanoma patients. EJNMMI Res. 2020;10:139.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Hall NC, Nichols SD, Povoski SP, James IAO, Wright CL, Harris R, et al. Intraoperative use of a portable large field of view gamma camera and handheld gamma detection probe for radioguided localization and prediction of complete surgical resection of Gastrinoma: proof of concept. J Am Coll Surg. 2015;221:300–8.

Article  PubMed  Google Scholar 

Alci E, Ozdemir M, Miftari A, Oral A, Gumus T, Icoz G, et al. Intraoperative freehand SPECT as an alternative imaging technique for use in radioguided parathyroidectomy. Updates Surg. 2022;74:1429–34.

Article  PubMed  Google Scholar 

Schilling C, Gnansegaran G, Thavaraj S, McGurk M. Intraoperative sentinel node imaging versus SPECT/CT in oral cancer—a blinded comparison. Eur J Surg Oncol. 2018;44:1901–7.

Article  PubMed  Google Scholar 

Yamamoto S, Higashi T, Matsumoto K, Senda M. Preliminary study for the development of a tweezers-type coincidence detector for tumor detection. Nucl Instrum Methods Phys Res A. 2005;548:564–70.

Article  CAS  Google Scholar 

Yamamoto S, Sakamoto Y, Matsumoto K, Senda M. Development of a tweezers-type coincidence imaging detector. Ann Nucl Med. 2008;22:387–93.

Article  PubMed  Google Scholar 

Takahashi M, Yoshimura S, Takyu S, Aikou S, Okumura Y, Yagi K, et al. A design of forceps-type coincidence radiation detector for intraoperative LN diagnosis: clinical impact estimated from LNs data of 20 esophageal cancer patients. Ann Nucl Med. 2022;36:285–92.

Article  CAS  PubMed  Google Scholar 

Raylman RR, Fisher SJ, Brown RS, Ethier SP, Wahl RL. Fluorine-18-Fluorodeoxyglucose-guided breast cancer surgery with a positron-sensitive probe: validation in preclinical studies. J Nucl Med. 1995;36:1869–74.

CAS  PubMed  Google Scholar 

Levin CS, Tornai MP, MacDonald LR, Hoffman EJ. Annihilation/spl gamma/-ray background characterization and rejection for a small beta camera used for tumor localization during surgery. IEEE Trans Nucl Sci. 1997;44:1120–6.

Article  CAS  Google Scholar 

Yamamoto S, Matsumoto K, Sakamoto S, Tarutani K, Minato K, Senda M. An intra-operative positron probe with background rejection capability for FDG-guided surgery. Ann Nucl Med. 2005;19:23–8.

Article  PubMed  Google Scholar 

Sabet H, Stack BC, Nagarkar VV. A hand-held, intra-operative positron imaging probe for surgical applications. IEEE Trans Nucl Sci. 2015;62:1927–34.

Article  CAS  Google Scholar 

Povoski SP, Hall NC, Murrey DA, Chow AZ, Gaglani JR, Bahnson EE, et al. Multimodal imaging and detection approach to 18F-FDG-directed surgery for patients with known or suspected malignancies: a comprehensive description of the specific methodology utilized in a single-institution cumulative retrospective experience. World J Surg Oncol. 2011;9:152.

Article  PubMed  PubMed Central  Google Scholar 

Arabi H, Manesh AS, Zaidi H. Innovations in dedicated PET instrumentation: from the operating room to specimen imaging. Phys Med Biol. 2024;69:11TR03.

Article  Google Scholar 

Solomon SB, Cornelis F. Interventional molecular imaging. J Nucl Med. 2016;57:493–6.

Article  CAS  PubMed  Google Scholar 

Tashima H, Yoshida E, Kinouchi S, Nishikido F, Inadama N, Murayama H, et al. Real-time imaging system for the OpenPET. IEEE Trans Nucl Sci. 2012;59:40–6.

Article  Google Scholar 

Tashima H, Yoshida E, Inadama N, Nishikido F, Nakajima Y, Wakizaka H, et al. Development of a small single-ring OpenPET prototype with a novel transformable architecture. Phys Med Biol. 2016;61:1795–809.

Article  PubMed  Google Scholar 

Tashima H, Yoshida E, Iwao Y, Wakizaka H, Mohammadi A, Nitta M, et al. Development of a multiuse human-scale single-ring OpenPET system. IEEE Trans Radiat Plasma Med Sci. 2021;5:807–16.