Rutkūnas V, Auškalnis L, Pletkus J. Intraoral scanners in implant prosthodontics. A narrative review. J Dent. 2024;148: 105152. https://doi.org/10.1016/j.jdent.2024.105152.
Afrashtehfar KI, Alnakeb NA, Assery MKM. Accuracy of intraoral scanners versus traditional impressions: a rapid umbrella review. J Evid Based Dent Pract. 2022;22(3):101719. https://doi.org/10.1016/j.jebdp.2022.101719.
Michelinakis G, Apostolakis D, Kamposiora P, Papavasiliou G, Özcan M. The direct digital workflow in fixed implant prosthodontics: a narrative review. BMC Oral Health. 2021;21(1):37. https://doi.org/10.1186/s12903-021-01398-2.
Article CAS PubMed PubMed Central Google Scholar
Siqueira R, Galli M, Chen Z, Mendonça G, Meirelles L, Wang HL, Chan HL. Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review. Clin Oral Investig. 2021;25(12):6517–31. https://doi.org/10.1007/s00784-021-04157-3.
Article PubMed PubMed Central Google Scholar
Borbola D, Berkei G, Simon B, et al. In vitro comparison of five desktop scanners and an industrial scanner in the evaluation of an intraoral scanner accuracy. J Dent. 2023;129: 104391. https://doi.org/10.1016/j.jdent.2022.104391.
Donmez MB, Mathey A, Gäumann F, Mathey A, Yilmaz B, Abou-Ayash S. Scan accuracy and time efficiency of different implant-supported fixed partial denture situations depending on the intraoral scanner and scanned area: an in vitro study. J Prosthet Dent. 2024;131(6):1198–207. https://doi.org/10.1016/j.prosdent.2023.01.029.
Donmez MB, Mathey A, Gäumann F, Mathey A, Yilmaz B, Abou-Ayash S. Effect of intraoral scanner and fixed partial denture situation on the scan accuracy of multiple implants: an in vitro study. Clin Implant Dent Relat Res. 2023;25(3):502–10. https://doi.org/10.1111/cid.13190.
Abou-Ayash S, Mathey A, Gäumann F, Mathey A, Donmez MB, Yilmaz B. In vitro scan accuracy and time efficiency in various implant-supported fixed partial denture situations. J Dent. 2022;127:104358. https://doi.org/10.1016/j.jdent.2022.104358.
Article CAS PubMed Google Scholar
Ben-Izhack G, Rosner O, Zenziper E, et al. Comparison between conventional and digital impressions for determining axes and distances of three implants in straight and curved lines: an in vitro study. J Clin Med. 2024;13(8):2352. https://doi.org/10.3390/jcm13082352.
Article PubMed PubMed Central Google Scholar
Schmalzl J, Róth I, Borbély J, Hermann P, Vecsei B. The impact of software updates on accuracy of intraoral scanners. BMC Oral Health. 2023;23(1):219. https://doi.org/10.1186/s12903-023-02926-y.
Article PubMed PubMed Central Google Scholar
Turkyilmaz I, Lakhia S, Tarrida LG, Varvara G. Guest commentary: the battle of file formats from intraoral optical scanners. Int J Prosthodont. 2020;33:369–71. https://doi.org/10.11607/ijp.2020.4.gc.
Abad-Coronel C, Atria PJ, Romero Muñoz C, et al. Analysis of the mesh resolution of an STL exported from an intraoral scanner file. J Esthet Restor Dent. 2022;34(5):816–25. https://doi.org/10.1111/jerd.12889.
Mandelli F, Gherlone E, Gastaldi G, Ferrari M. Evaluation of the accuracy of extraoral laboratory scanners with a single-tooth abutment model: a 3D analysis. J Prosthodont Res. 2017;61(4):363–70.
ISO 5725–1. Accuracy (trueness and precision) of measurement methods and results—part 1: general principles and definitions.
Natsubori R, Fukazawa S, Chiba T, Tanabe N, Kihara H, Kondo H. In vitro comparative analysis of scanning accuracy of intraoral and laboratory scanners in measuring the distance between multiple implants. Int J Implant Dent. 2022;8:18. https://doi.org/10.1186/s40729-022-00416-4.
Article PubMed PubMed Central Google Scholar
Lebon N, Tapie L, Duret F, Attal JP. Understanding dental CAD/CAM for restorations–accuracy from a mechanical engineering viewpoint. Int J Comput Dent. 2015;18:343–67.
Ben-Izhack G, Lugassy D, Rosner O, et al. Post sterilization of intraoral scan body and the effect it has on the axes and distances between three adjacent implants: in-vitro study. BMC Oral Health. 2024;24(1):870. https://doi.org/10.1186/s12903-024-04664-1.
Article PubMed PubMed Central Google Scholar
Revilla-León M, Lanis A, Yilmaz B, Kois JC, Gallucci GO. Intraoral digital implant scans: parameters to improve accuracy. J Prosthodont. 2023. https://doi.org/10.1111/jopr.13749.
Michelinakis G, Apostolakis D, Nikolidakis D, Lapsanis G. Influence of different scan body design features and intraoral scanners on the congruence between scan body meshes and library files: an in vitro study. J Prosthet Dent. 2024;132(2):454.e1-454.e11. https://doi.org/10.1016/j.prosdent.2024.05.016.
Arcuri L, Pozzi A, Lio F, Rompen E, Zechner W, Nardi A. Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: a randomized in vitro trial. J Prosthodont Res. 2020;64:128–36.
Fluegge T, Att W, Metzger M, Nelson K. A novel method to evaluate precision of optical implant impressions with commercial scan bodies—an experimental approach. J Prosthodont. 2017;26:34–41.
Pachiou A, Zervou E, Tsirogiannis P, Sykaras N, Tortopidis D, Kourtis S. Characteristics of intraoral scan bodies and their influence on impression accuracy: a systematic review. J Esthet Restor Dent. 2023. https://doi.org/10.1111/jerd.13074.
Roig E, Roig M, Garza LC, Costa S, Maia P, Espona J. Fit of complete-arch implant-supported prostheses produced from an intraoral scan by using an auxiliary device and from an elastomeric impression: a pilot clinical trial. J Prosthet Dent. 2022;128(3):404–14. https://doi.org/10.1016/j.prosdent.2020.10.024.
Article CAS PubMed Google Scholar
Mangano FG, Hauschild U, Veronesi G, Imburgia M, Mangano C, Admakin O. Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study. BMC Oral Health. 2019;19(1):101. https://doi.org/10.1186/s12903-019-0792-7.
Article PubMed PubMed Central Google Scholar
Jivanescu A, Rotar P, Hategan S, Pricop C, Rus R, Goguta L. Clinical factors influence the trueness of intra-oral scanning. Eur J Prosthodont Restor Dent. 2019;27(1):51–5. https://doi.org/10.1922/EJPRD_01861Jivanescu05.
Article CAS PubMed Google Scholar
Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants. 1991;6(3):270–6.
Cohen SR, Orenstein JH. The use of attachments in combination implant and natural-tooth fixed partial dentures: a technical report. Int J Oral Maxillofac Implants. 1994;9(2):230–4.
Brunski JB. Influence of biomechanical factors at the bone-biomaterial interface. Bone-Biomaterial Interface. 1991;2:391–403.
Brånemark P-I, Zarb GA, Albrektsson T. Tissue-integrated prostheses: osseointegration in clinical dentistry. Chicago: Quintessence; 1985. p. 99–115.
Klineberg IJ, Murray GM. Design of superstructures for osseointegrated fixtures. Swed Dent J Suppl. 1985;28:63–9.
Stimmelmayr M, Güth JF, Erdelt K, Edelhoff D, Beuer F. Digital evaluation of the reproducibility of implant scanbody fit–an in vitro study. Clin Oral Investig. 2012;16(3):851–6. https://doi.org/10.1007/s00784-011-0564-5.
Hogg WS, Zulauf K, Mehrhof J, Nelson K. The influence of torque tightening on the position stability of the abutment in conical implant-abutment connections. Int J Prosthodont. 2015;28(5):538–41. https://doi.org/10.11607/ijp.3853.
Nedelcu R, Olsson P, Thulin M, Nyström I, Thor A. In vivo trueness and precision of full-arch implant scans using intraoral scanners with three different acquisition protocols. J Dent. 2023;128: 104308. https://doi.org/10.1016/j.jdent.2022.104308.